HI-99301 measures conductivity, total dissolved solids and temperature encountered in manufacturing and environmental settings. All operations, settings and temperature scale selections are made through only two buttons. The housing is waterproof and rated for IP67 conditions.
Benefits
Simultaneous EC/TDS and temperature measurements on a large LCD display
Selectable temperature unit
HI-763063 dedicated EC/TDS temperature probe
Probe quick-connect system with watertight connection (DIN)
Battery life indication and low battery detection
Auto-off function
Keystroke confirmation tone
Waterproof casing IP67
The supplied multi-parameter probe, HI-763063, includes EC/TDS and temperature in one convenient, rugged probe. Other user-selectable features include different TDS factors from 0.45 to 1.00 and a range of temperature coefficients (√Öí√¢â§) from 0.0 to 2.4% for better solution temperature compensation.
Each meter is supplied complete with:
HI-763063 pH/EC/TDS probe with a built-in temperature sensor, DIN connector and 1m cable
HI-70030 12880 µS/cm and HI-70038 6.44 ppt 1 sachet each
100mL beaker
Alkaline batteries: 1.5V AAA x 3
Rugged carrying case
Calibration certificate of meter
Calibration certificate of the probe
Instruction manual
Specifications
Range
√¢Äö√ÉÑ√ÉâEC
0 to 20.00 mS/cm (displays mS)
√¢Äö√ÉÑ√ÉâTDS
0.00 to 10.00ppt
√¢Äö√ÉÑ√ÉâTemp
-5.0 to 105.0℃
Resolution
√¢Äö√ÉÑ√ÉâEC
0.01 mS/cm
√¢Äö√ÉÑ√ÉâTDS
0.01 ppt (g/L)
√¢Äö√ÉÑ√ÉâTemp
0.1℃
Accuracy @ 20℃
±2% F.S. (EC/TDS); ±0.5℃ temp
Temperature Compensation
Automatic, with √Öí√¢â§ selectable from 0.0 to 2.4%/℃ with 0.1 increments
EC/TDS Calibration
Automatic, one-point at 12.88mS/cm or 6.44 ppt (CONV=0.5) or 9.02 ppt (CONV=0.7)
TDS Conversion factor
Selectable from 0.45 to 1.00 with 0.01 increments
Probe (included)
HI-763063 EC/TDS/Temperature sensor, DIN connector and 1m cable
Our standard delivery is 3-5 working days (where products are available) Monday to Friday, excluding public holidays when you order by 2pm. Details of our returns and cancellation policy can be found in our Returns Policy & Section 11 of our Terms and Conditions. For more information please contact us on 01924 444 577 or Email Us.
Conductivity / Total Dissolved Solids / Salinity / Temperature
Backlit, rugged waterproof meter is ideal for any environment
Durable waterproof and dustproof design with IP67 rating
Large, backlit custom display – View measurement with temperature and cell efficiency
Grip-Clip™ – Quickly and easily secures the probe to your beaker or container
Calibrate using automatically recognized standards or manually; to a single point across all ranges or to multiple points (one calibration point per each conductivity range)
Selectable cell constant – 0.10, 1.00, or 10.0
Adjustable temperature coefficient from 0.00 to 10.00 % per ºC. Set to 0.0 % to meet USP methods for non-compensated measurements
Adjustable conductivity-to-TDS factor – Adjustable 0.4 to 1.0
Selectable ºC / ºF – Choose units to best fit your application
Includes easy to clean conductivity cell
Ready indicator, manual or automatic measurement hold feature and optional automatic shutoff function
Store up to 500 data sets with data – Use USB or RS232 output with optional data cable to send data to your software or free communication software
Built-in real-time clock stamps stored data and calibration data with time and date –
Meets standards for GLP (Good Laboratory Practices)
Built-in stand with wall-mount – Allows for easy benchtop measurement or storage
pH / mV / Conductivity / Total Dissolved Solids / Salinity / Temperature
PC 450 accepts a single pH/Con probe or separate pH and conductivity probes
Durable waterproof and dustproof design with IP67 rating
Switch between pH, mV, conductivity, TDS and salinity with a press of a button
Large, backlit custom display – Lets you view measurement with temperature
Grip-Clip™ – Quickly and easily secures separate pH and conductivity electrodes simultaneously to your sample container or beaker
Calibrate up to 5 points automatically with USA or NIST buffer groups (up to 6 points with DIN). New manual option allows calibration with up to 5 custom buffer standards you
Auto buffer recognition – Automatically identifies the correct pH buffer for rapid calibration
Calibration due alarm – Set a visible reminder when it is time to recalibrate the meter
Intuitive, user-friendly icons – Electrode status displays pH slope or cell constant
Auto-range conductivity from 0 to 199.9 mS in five ranges – With up to five calibration points
Selectable cell constant – 0.10, 1.00 or 10.0
Adjustable temperature coefficient – From 0.00 to 10.00 % per ºC
Conductivity-to-TDS factor – Adjustable from 0.40 to 1.00
Selectable ºC/ºF – Choose units to best fit your application
Ready indicator, manual or automatic measurement hold feature and optional automatic shutoff function
Store up to 500 data sets; easy USB or RS232 output with optional data cables
Built-in real-time clock stamps stored data and calibration data with time and date –
Meets standards for GLP (Good Laboratory Practices)
500 hours battery life or use an optional universal power adapter
Built-in stand with wall-mount – Allows for easy benchtop measurement and storage